Implantable Networks of Wireless Nanoelectronic Devices

By Pedro Irazoqui

Biomedical Engineering, Purdue University, West Lafayette, IN

Published on

Bio

Pedro Irazoqui Dr. Irazoqui received his B.Sc. and M.Sc. degrees in Electrical Engineering from the University of New Hampshire, Durham in 1997 and 1999 respectively, and the Ph.D. in Neuroengineering from the University of California at Los Angeles in 2003 for work on the design, manufacture, and packaging, of implantable integrated-circuits for wireless neural recording.

He is director of Purdue’s Center for Implantable Devices, associate head for research and associate professor in the Weldon School of Biomedical Engineering, and associate professor of electrical and computer engineering. His group develops wireless implantable devices for various potential applications including monitoring and suppression of epileptic seizures; prosthesis control for injured military personnel; modulation of cardiac arrhythmias; treatment of depression, and gastroparesis, a partial paralysis of the stomach; and monitoring and therapeutic modulation of intraocular pressure for glaucoma.

He has been named Showalter Faculty Scholar, and Purdue University Faculty Scholar, both in 2013. He is a senior member of IEEE. He has received the Best Teacher Award from the Weldon School of Biomedical Engineering (2006 & 2009), the Early Career Award from the Wallace H. Coulter Foundation (2007 & Phase II in 2009), the Marion B. Scott Excellence in Teaching Award from Tau Beta Pi (2008), and the Outstanding Faculty Member Award from the Weldon School of Biomedical Engineering (2009), as well as the Excellence in Research Award from Purdue in 2010, 2012 and 2013. He has been serving as Associate Editor of IEEE Transactions on Biomedical Engineering since late 2006.

Cite this work

Researchers should cite this work as follows:

  • Pedro Irazoqui (2014), "Implantable Networks of Wireless Nanoelectronic Devices," https://nanohub.org/resources/21448.

    BibTex | EndNote

Time

Location

Birck Technology Center, Room 1001, Purdue University, West Lafayette, IN

Implantable Networks of Wireless Nanoelectronic Devices
  • Implantable Networks of Wireless Nanoelectronic Devices 1. Implantable Networks of Wirele… 0
    00:00/00:00
  • Medical marketplace 2. Medical marketplace 255.58892225558893
    00:00/00:00
  • Goal 3. Goal 279.41274607941278
    00:00/00:00
  • Outcome 4. Outcome 336.00266933600267
    00:00/00:00
  • Outline 5. Outline 345.81247914581252
    00:00/00:00
  • Mouse intraocular pressure sensor 6. Mouse intraocular pressure sen… 457.29062395729062
    00:00/00:00
  • Chronic bioelectric recording 7. Chronic bioelectric recording 749.88321654988329
    00:00/00:00
  • Our alternative 8. Our alternative 864.53119786453124
    00:00/00:00
  • Outline 9. Outline 1085.1184517851184
    00:00/00:00
  • Dosing: autonomous neural control 10. Dosing: autonomous neural cont… 1094.9282615949282
    00:00/00:00
  • ANC: 11. ANC: 1132.7994661327996
    00:00/00:00
  • ANC: 12. ANC: 1165.1317984651319
    00:00/00:00
  • ANC: 13. ANC: 1290.8241574908243
    00:00/00:00
  • ANC: 14. ANC: 1291.8251584918253
    00:00/00:00
  • ANC: 15. ANC: 1294.9949949949951
    00:00/00:00
  • Optogenetics: 16. Optogenetics: "state-of-the-ar… 1297.4307640974307
    00:00/00:00
  • Slide 17: Untitled 17. Slide 17: Untitled 1418.0513847180514
    00:00/00:00
  • Combining ANC & OGS 18. Combining ANC & OGS 1493.1931931931933
    00:00/00:00
  • Outline 19. Outline 1539.205872539206
    00:00/00:00
  • Powering 20. Powering 1546.3129796463131
    00:00/00:00
  • Frequency selection 21. Frequency selection 1641.574908241575
    00:00/00:00
  • Antenna design 22. Antenna design 1709.5095095095096
    00:00/00:00
  • Powering: demo 23. Powering: demo 1718.2849516182851
    00:00/00:00
  • Power storage 24. Power storage 1747.6142809476144
    00:00/00:00
  • Outline 25. Outline 2067.2339005672338
    00:00/00:00
  • Microchips: 26. Microchips: 2078.511845178512
    00:00/00:00
  • Glaucoma 27. Glaucoma 2096.2629295962629
    00:00/00:00
  • Seizure monitoring 28. Seizure monitoring 2150.2168835502171
    00:00/00:00
  • Congestive heart failure 29. Congestive heart failure 2164.2308975642309
    00:00/00:00
  • Electromyography 30. Electromyography 2173.5402068735402
    00:00/00:00
  • The microchips shown were designed and assembled at Purdue 31. The microchips shown were desi… 2180.2469135802471
    00:00/00:00
  • The microchips shown were designed and assembled at Purdue 32. The microchips shown were desi… 2197.5975975975975
    00:00/00:00
  • The microchips shown were designed and assembled at Purdue 33. The microchips shown were desi… 2201.0343677010346
    00:00/00:00
  • The microchips shown were designed and assembled at Purdue 34. The microchips shown were desi… 2204.8715382048717
    00:00/00:00
  • The microchips shown were designed and assembled at Purdue 35. The microchips shown were desi… 2207.5075075075074
    00:00/00:00
  • NEEDS: 36. NEEDS: 2251.4848181514849
    00:00/00:00
  • NEEDS: 37. NEEDS: 2275.1084417751085
    00:00/00:00
  • Packaging: 38. Packaging: 2298.4651317984653
    00:00/00:00
  • Miniaturization 39. Miniaturization 2337.5375375375374
    00:00/00:00
  • Miniaturization 40. Miniaturization 2341.2746079412746
    00:00/00:00
  • Miniaturization 41. Miniaturization 2344.577911244578
    00:00/00:00
  • Further miniaturization 42. Further miniaturization 2361.5615615615616
    00:00/00:00
  • Neworked wireless nano-implants 43. Neworked wireless nano-implant… 2470.5038371705041
    00:00/00:00