Please be advised that the date of scheduled maintenance has been changed to Monday, June 17, 2024 beginning at approximately 8 am PDT/11 am EDT. Expect a minimum downtime of approximately 4 hours, barring any difficulties. All running tool sessions will expire during the maintenance window, please plan accordingly. We apologize for any inconvenience.
close
Powered by nanoHUB.org
Close

Liquid Dispersion Waste Management Controls

Operation

Disposal of liquid nanodispersion waste

Controls

  • Damp laboratory wipes shall be used to minimize particulate generation
    • The wipes must be compatible with the solvents used in the dispersion
    • Laboratory wipes shall be disposed of in closed receptacles that are in a ventilated enclosure
  • Latex or nitrile clean room gloves
    • Contaminated gloves must be disposed of in closed receptacles that are in a ventilated enclosure
  • When exhaust ventilation is not feasible, respiratory protection shall be utilized to prevent potential inhalation of nanomaterials

Note: Additional PPE and or EHS controls may be required based on the suspension solvent selection.

Alternatively, Control Banding may be employed when more is known about material reactivity, exposure duration and material state.